  • Specs Summary

3516E Low Voltage Generator Set

Producing reliable power from 2750 kVA to 3000 kVA (3100 kVA without fan) at 50 Hz, our 3516E diesel generator sets are made to match your mission critical, standby and prime applications, and meet our quality standards. We've engineered each to ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. Seismic certification is also available for select models, maintaining power after unexpected disturbances. The integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. Our EMCP 4 control panel provides flexible options, with a user-friendly interface, putting your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to provide expanded capacity and generator set redundancy to match your requirements. No two power needs are the same, which is why we offer a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging options to work with your spatial requirements and environmental conditions. Our 3516E generator sets are built to take on power challenges — customize them to take on yours.

Standard Equipment

Air Inlet System

  • Air cleaner
  • Single element canister type with service indicator

Control Panel

  • EMCP 4.2
  • Emergency stop pushbutton
  • Panel lights
  • EMCP4.2 controller includes:
  • 24-volt DC operation
  • Environmental sealed front face
  • Text alarm / event descriptions
  • Generator mounted - rear facing
  • Controls:
  • Speed adjust
  • Engine cool-down timer
  • Engine cycle crank
  • Alarm acknowledge
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • RPM
  • DC volts
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • kW-hr (total)
  • kVAr-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Low oil pressure
  • High coolant temperature
  • Overspeed
  • Emergency stop
  • Failure to start (overcrank)
  • Low coolant temperature
  • Low coolant level
  • Programmable protective relaying functions:
  • Generator phase sequence
  • Over / under voltage (27/59)
  • Over / under frequency (81 o/u)
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • Communications:
  • Customer data link (Modbus RTU)
  • Accessory module data link
  • Serial annunciator module data link
  • 6 programmable digital inputs
  • 4 programmable relay outputs (Form A)
  • 2 programmable relay outputs (Form C)
  • 2 programmable digital outputs

Cooling System

  • JWAC
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant drain line with valve
  • Coolant level sensors
  • Caterpillar Extended Life Coolant

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump

Generators and Attachments

  • 3 phase brushless, salient pole
  • 6 lead
  • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • Random wound
  • Internal excitation
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).
  • Winding temperature detectors
  • Bus bar connections, top center mounted, top cable entry
  • IEC standard hole pattern

Governing System

  • ADEM III

Literature

  • English

Lube System

  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cooler
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal

Mounting System

  • Rails - engine / generator / radiator mounting
  • Rubber anti-vibration mounts (shipped loose)

Starting / Charging System

  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

General

  • Paint: Caterpillar yellow with high gloss black rails & radiator
  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation

Optional Equipment

Air Inlet System

  • Dual element air cleaners
  • Heavy duty air cleaners
  • Remote air inlet adapters
  • Air inlet protection

Power Termination

  • Circuit breakers, IEC compliant

Circuit Breakers

  • Optional busbar power connections
  • Load take off; IEC standard hole
  • Center posts busbars
  • Cable entry options
  • Control packaging for enclosures
  • Trip Units
  • EMAX breakers

Control Panels

  • EMCP 4.3, EMCP 4.4
  • Language options
  • Busbar connections
  • EMAX breaker connections
  • Annunciator modules
  • Governors
  • External box clips
  • Auxiliary box
  • Customer interface options
  • Generator temperature monitoring
  • Voltage raise / lower switch
  • Remote speed adjust
  • Vandal proof panel door
  • Local and remote monitoring

Cooling System

  • Optional Serpentine radiators
  • Water level switch gauges
  • Heat exchangers
  • Radiator duct flanges

European Certifications

  • EU declaration of conformity

Exhaust System

  • Mufflers
  • Muffler mounting kits
  • Flexible fittings
  • Through wall installation kit

Fuel System

  • Primary fuel filter
  • Fuel coolers

Generators and attachments

  • Optional generators
  • 3 Phase, Random wound, Internal excitation
  • Number of leads: 6
  • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt<br />  
  • Random wound
  • Internal excitation
  • Pitch: 0.6667

Instrumentation

  • Pyrometers and thermocouples

Lube System

  • Oil level reg-1 shallow pan
  • Electric prelube pumps
  • Manual prelube sump pumps

Mounting System

  • Spring type vibration isolators
  • IBC vibration isolators

Protection System

  • Explosion relief valves

Special Tests / Reports

  • CSA test and certification
  • Neutral ground certificate
  • IBC seismic certificate
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor

Starting / Charging System

  • Charging alternators - 50 Amp
  • 10 and 20 amp battery chargers
  • 24 Volt battery sets - Dry
  • Dual 24 volt electric starting motors
  • ETHER starting aids
  • Jacket water heaters

General

  • Engine barring group