Electric Power

  • Specs Summary
  • Rating Range
    120 to 480V, single phase and three phase @ 50/60 Hz
  • Transfer Type
    Switch application dependent
  • Switch Type
    Switch application dependent
  • Input control voltage
    95 to 145 Vac 50/60 Hz

ATC-100 CONTROLLER

The ATC-100 is a comprehensive and multifunctional microprocessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels.The ATC provides both fixed and jumper-selectable settings to allow for a range of applications. It operates from all system voltages between 120 and 480 Vac, single-phase and three phase at 50 or 60 Hz. The ATC-100 monitors the condition of the three-phase line to line voltage and the frequency of both the utility and generator power sources. It can also be set up for single-phase operation. The ATC-100 provides the necessary intelligence to ensure that the transfer switch operates properly through a series of selectable sensing and timing functions.

Technical Summary

  • Rating Range 120 to 480V, single phase and three phase @ 50/60 Hz
  • Transfer Type Switch application dependent
  • Switch Type Switch application dependent

ATC Controller Specifications

  • Input control voltage 95 to 145 Vac 50/60 Hz
  • Voltage measurements of Utility VAB generator VAB
    VBC generator VBC
    VCA generator VCA
  • Voltage measurement range 0 to 575 Vac rms (50/60 Hz)
  • Voltage measurement accuracy ± 1% of full scale
  • Frequency measurements of Generator
  • Frequency measurement range 40 Hz to 70 Hz
  • Frequency measurement accuracy ±0.3 Hz over the measurement range
  • Undervoltage dropout 80% of the nominal system voltage
  • Undervoltage pickup 90% of the nominal system voltage
  • Underfrequency dropout range 90% of the nominal system frequency
  • Underfrequency pickup range 95% of the nominal system frequency
  • Overfrequency dropout range 115% of the nominal system frequency
  • Overfrequency pickup range 110% of the nominal system frequency
  • Operating temperature range –20 to +70°C (–4 to +158°F)
  • Storage temperature range –30 to +85°C (–22 to +185°F)
  • Operating humidity 0 to 95% relative humidity (noncondensing)
  • Operating environment Resistant to ammonia, methane, nitrogen, hydrogen and hydrocarbons
  • Generator start relay 5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load
  • K1, K2 relays
    10A, 1–3 hp @ 250 Vac

    10A@30 Vdc
  • Applicable testing UL-recognized component
    UL 1008, UL 991 Environmental IEC 61000-4-2, 61000-4-3, 61000-4-4,
  • Applicable testing continued 61000-4-5, 61000-4-6, 61000-4-11
    CISPR 11, Class B
    FCC Part 15, Class B
    CSS 22.2-178
  • Enclosure compatibility NEMA 1, NEMA 3R and NEMA 12
    UV-resistant ATC-100 faceplate